 Adria Vision Electrics Problem
624275 Post Posted: Fri May 08, 2009 2:54 pm Thank this member for this postReply with quote

Bacchus Subscriber 14/05/2010 

Joined: Mar 27, 2008

Posts: 129

Thanked 7 times in 7 posts

MH: Autotrail Chieftain

Campsites

blank.gif

Status: Offline

This problem was discovered by a Truma technician whilst checking my Adria Vision's combi boiler. The 240v electrical circuits are protected by a 10amp double pole MBC. If I switch all the habitation equipment on in the motorhome, the current draw exceeds 10amps and that's why I am constantly having my supply interrupted. I can only really use the 240v sockets if I turn pretty much everything else off. Could someone describe there own Vision MCBs to me, please. I think I need a higher rated MCB - I'm amazed there's only one! A total of 16amps would make sense to me. Any advice would be appreciated
 
624280 Post Posted: Fri May 08, 2009 3:09 pm Thank this member for this postReply with quote

SaddleTramp Subscriber 03/03/2011 

Joined: Feb 15, 2007

Posts: 1191

Thanked 268 times in 229 posts

MH: Kountrylite SE 26RL 5ver

Campsites

Location: Brimington, Chesterfield, Derbyshire

uk.gif

Status: Offline

Hi Mate, Here is a Photo of mine also on the Adria I707, By the way I have no problems with tripping out or anything.

______________________________________________________________
All The Best
Les


The World is Only as Big as You Think it is,

If you Think you Canīt - You Wonīt.
 Electrics
624450 Post Posted: Fri May 08, 2009 7:13 pm Thank this member for this postReply with quote

Tommo  

Joined: May 01, 2005

Posts: 23

Thanked 1 times in 1 posts

MH: Adria Izola

Campsites

Location: Portsmouth

uk.gif

Status: Offline

I had the same problem with my Izola. I coudn't even boil a kettle

I had 16 amp MCB's fitted
 
624494 Post Posted: Fri May 08, 2009 8:25 pm Thank this member for this postReply with quote

gaspode Subscriber 31/12/2010 

Moderator

Joined: May 09, 2005

Posts: 8647

Thanked 575 times in 522 posts

MH: Arto 69P

Campsites

Location: Exiled in Surrey

blank.gif

Status: Offline

The rating of the MCBs would normally be matched to protect the wiring on the appliance side of the MCB therefore if a 10amp MCB is fitted you must establish why such a low value MCB has been fitted (and make any necessary alterations) before simply fitting a higher rated unit. It is very likely that the wiring or some other component in the van is unsuitable for currents in excess of 10amps. If the installation was suitable to handle 16amps, a 16amp breaker would have been fitted as original equipment, manufacturers are not usually noted for under-rating their products.

______________________________________________________________
"Inside every old person is a young person wondering what happened" - Terry Pratchett
wave
 
624590 Post Posted: Fri May 08, 2009 10:50 pm Thank this member for this postReply with quote

Bacchus Subscriber 14/05/2010 

Joined: Mar 27, 2008

Posts: 129

Thanked 7 times in 7 posts

MH: Autotrail Chieftain

Campsites

blank.gif

Status: Offline

Yes, Gaspode, what you say makes sense. So why is ALL the 240v wiring passing thrugh a single 10amp MCB. My wiring looks nothing like Saddletramp's. I'll take a pick in the morning. What I was thinking of doing was to get an ellectrician to go through the wiring with a view to fitting an additional 10amp MCB and splitting the wiring between the two. That way the rating remains unchanged. I've never seen four wires stuffed into one trip switch. Looks quite dangerous to me. Wouldn't be allowed in house wiring !!
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum