Welcome to Motorhomefacts, we are a thriving motorhome community (Largest in Europe). Why Not JOIN NOW and get instant access to more of the website. It costs nothing to join and only takes a few minutes. We have 200,000 different people visiting our site monthly and this amount of motorhomers in one place guarantees a fast response to any questions you may have. We also have unique facilities not found elsewhere such as our Online Logbook, stopover tracker, Motorhome directory with Ebay type feedback and the largest repository of motorhome campsites reviews found anywhere
Hi,
we have Advantage 7871 lovely van, but has anyone had trouble with the kitchen tap, the micro switch packs up and we are getting through 2 switches a year.
We and the same problem and frankly there is nothing you can do about
it.
It comes down to the poor design of the tap which means the cable is being twisted and flexed every time it is used. Eventually the metal just hardens and breaks.
We now carry a couple of spare micro switches to change out when necessary.
OK - on reflection - you can. If you replace the wires on the micro switch with something that will resist the constant twisting (ie a braided cable) but then you might have difficulty getting the new cables through the tap housing.
The thing to do is convert the system from micro-switches to a single pressure switch. That's what we did on our Arto when one of the tap switches kept failing.
It's fairly simple (and cheap) to do in principle but you might have problems with the odd hose joint leaking when under pressure. I fitted new hose clips to all the joints on the principle that if they were leaking under pressure, sooner or later they'd leak on the micro-switch system anyway.
Any competent mobile motorhome engineer would be able to do it for you if you dan't want to tackle the job yourself.
______________________________________________________________ If you lend someone £20 and never see that person again, it was probably well worth it.
Thanks guys for the responses.
We're going to the show at the excel so will see if we can find a replacement, but not sure if its possible.
I have been told it's to do with us having a submerged water pump we are stuck with microswitch taps, if we changed to a pressurised pump then we could change the tap, might have to look at this option too.
Not had the above system so excuse my ignorance if this is not doable.
Could you not disable the tank pump by removing the fuse,and then put a Shurflo pump somewhere close by take the exit pipe from original pump and replace the taps and put normal pressure switch in line.
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum You cannot attach files in this forum You cannot download files in this forum